What Size Air Conditioner Do I Need? A Split System Size Guide for Melbourne Homes

Short answer: in most Melbourne homes, a bedroom needs a 2.5 to 3.5 kW split system, a lounge 3.5 to 6 kW, and an open-plan living area 6 to 9 kW. Go up a size for high ceilings, poor insulation, big west-facing windows or an upstairs room. Check the heating figure too, because Melbourne winters work these units hardest.

Below: how to get close on your own, what pushes the number up or down, and what a complete supply and install covers, from the unit and pipework to the circuit and switchboard. It’s November, so if you want cooling running before the first proper heatwave, now is the time to lock in a quote.

[IMAGE 1: electrical-powerhaus-up-the-ladder-p113.jpg]

What does “size” actually mean on an air conditioner?

Size is output, not the physical box. It’s measured in kilowatts (kW) and tells you how much heat the unit can pull out of a room in summer or put into it in winter. A 2.5 kW unit and a 7.1 kW unit can look almost the same on the wall.

Every reverse cycle split system has two output figures:

  • Cooling capacity, the number in the model name (2.5, 3.5, 5.0, 7.1 and so on).
  • Heating capacity, which is usually a bit higher than the cooling figure on the spec sheet.

The kW figure is not what the unit draws from your switchboard. A 5 kW unit uses far less than 5 kW of electricity.

What size split system do I need for each room?

Start with floor area. Measure length by width in metres and multiply. If two rooms are joined with no door between them, measure them as one space.

This table assumes a standard 2.4 m ceiling, an insulated ceiling and normal-sized windows. Treat it as a starting range, not a final answer.

RoomTypical floor areaSuggested split system size
Small bedroom or studyUp to 15 m²2.0 to 2.5 kW
Main bedroom or bedroom with ensuite15 to 25 m²2.5 to 3.5 kW
Small lounge or family room25 to 35 m²3.5 to 5.0 kW
Large lounge or living room35 to 50 m²5.0 to 7.1 kW
Open-plan kitchen, living and dining50 to 70 m²6.0 to 9.0 kW
Very large open plan, over 70 m²70 m² plusTwo units, a multi-head system or ducted

Choice found many sizing charts overshoot. Their calculator runs put a 30 m² Melbourne room at roughly 2.8 kW, where plenty of charts suggest 3.5 to 5 kW. So the low end of each range often suits a well-insulated single-storey room, and the high end is for rooms that cop the sun.

What changes the size you need?

Floor area gets you in the ballpark. These factors move you up or down within the range, or into the next size.

Ceiling height. The table assumes 2.4 m. A common rule of thumb is to add about 10% for every extra 30 cm of height. Period homes in Melbourne’s inner east and north with 3 m plus ceilings often need a size up.

Insulation. Ceiling insulation makes the biggest difference. In Choice’s testing, the same 30 m² room needed about a quarter more capacity with no roof insulation. If your ceiling insulation is thin, old or missing, go up a step, or fix the insulation first and buy the smaller unit.

West-facing windows and glass area. A lounge with big west-facing windows can be hotter at 5 pm than a room twice its size on the south side. Large sliding doors, bi-folds and skylights all add heat in summer and lose it in winter. Lots of glass, especially without external shading or decent blinds, means stepping up.

Top floor or ground floor. Heat rises and upstairs rooms sit right under the roof. An upstairs bedroom of 16 m² can need what a 22 m² ground floor bedroom needs. Ground floor rooms on a concrete slab usually sit at the lower end.

Open plan. Air doesn’t stop at an imaginary line between the kitchen and the lounge. Size for the whole connected space, including any staircase open to the floor above. One unit at the end of a long room can also struggle to reach the far end.

Melbourne’s climate. We get a handful of hot, dry 38 to 40 degree days each summer, then months of cold mornings. Melbourne is a heating-dominated city.

[IMAGE 2: electrical-powerhaus-tested-before-touched-p016.jpg]

Split system outdoor unit installed on stands beside a brick Melbourne home

Should I size for cooling or heating in Melbourne?

For most Melbourne homes, size for heating. A reverse cycle split system is one of the cheapest ways to heat a room, and most households here run it more in June than in January.

The catch is that heating output drops as it gets colder outside. The spec sheet figure is measured on a mild day, and on a 2 degree July morning the unit delivers less. The Zoned Energy Rating Label (the energy label with the map of Australia) shows how each model performs in hot, average and cold zones. Melbourne sits in the cold zone, so compare cold zone ratings between models of similar capacity.

In practice: if a room sits on the edge between two sizes and you plan to use the unit as your main heater, take the bigger one.

What happens if the air conditioner is too small or too big?

Too small. The unit runs flat out on the hottest and coldest days and still doesn’t get the room where you want it. It works harder, uses more power than it should and wears out sooner.

Too big. An oversized unit hits the set temperature fast, switches off, then starts again. That short cycling means uneven temperatures, poor moisture removal on humid days, higher running costs and more wear. It also costs more to buy.

The aim is the right size, or just slightly over. If a room needs 6 kW, a 6 to 6.5 kW unit is the right pick, not 8 kW.

Single split, multi-head or ducted?

  • Single split system. One indoor unit, one outdoor unit. Best for a bedroom, a lounge or one open-plan area, and the quickest to install.
  • Multi-head split. Two or more indoor units on one outdoor unit. Handy where outdoor space is tight, but if that outdoor unit fails, every connected room goes down.
  • Ducted. One large system feeding ceiling vents, with zones. Suits whole-home heating and cooling but is a bigger job and draws far more current. Some need three-phase power.

Many Melbourne homes end up with a mix: a larger unit in the living area and smaller units in the bedrooms.

What does a full split system install involve?

Most sizing guides stop at the kW figure, but the install is where jobs get held up. A split system install covers the unit itself, the refrigerant pipework between the indoor and outdoor units, the gas charge, commissioning, and the electrical work that feeds it all. At Electrical Powerhaus one team handles every part of that: sizing advice, supplying the unit, mounting both halves, running and charging the pipework, commissioning, the dedicated circuit and a switchboard upgrade if your board needs one. You deal with one company from quote to handover, with no second trade to book and no gap between the gas side and the power side.

Supply and install. We recommend a unit sized for the room and the way you’ll use it, supply it, and fit the indoor and outdoor units where they’ll work best: the indoor head where air can reach the whole space, the outdoor unit somewhere with airflow and easy service access.

Pipework, gas and commissioning. We run the refrigerant pipework, pressure test it, charge the system and commission it, then check heating and cooling output before we leave. You get shown how to use the controller and how to clean the filters.

A dedicated circuit. Each split system should have its own circuit from the switchboard, with the right size circuit breaker and safety switch protection. Running a new unit off an existing power circuit is a common cause of nuisance tripping.

Switchboard capacity. Your switchboard needs a spare spot for the new circuit and room for a safety switch. Adding two or three units at once means checking the board can carry the extra load without tripping.

Older switchboards. If your home still has an old ceramic fuse board, or a board with no safety switches and no spare space, it may need an upgrade before any new air conditioning circuit can go in. Finding that out at quote time beats finding out on install day. See our switchboard upgrades page for what that involves.

Outdoor isolator. The wiring rules require an isolating switch next to the outdoor unit so it can be switched off safely for servicing. If you’re replacing an old unit, we check the old isolator too, since years of weather take their toll.

Bigger systems. Larger splits and ducted units draw more current, so we check your supply and if three-phase power is needed.

Because the same team does the electrical work and the air conditioning install, the switchboard check happens at quote time, not on install day. You’ll get one fixed written quote covering the unit, the install and any electrical work, after we’ve checked the board.

[IMAGE 3: electrical-powerhaus-before-old-ceramic-fuse-board-p063.jpg] [IMAGE 4: electrical-powerhaus-after-new-switchboard-with-safety-switches-p064.jpg]

Old ceramic fuse board that needs an upgrade before adding an air conditioner circuit
New switchboard with safety switches ready for a split system circuit

Quick sizing checklist: 4 questions

Answer these four questions for the room you want to cool and heat.

  1. How big is the space? Measure floor area in m², including any open area with no door between. Use the table above to pick your starting size.
  2. How high is the ceiling? Standard (about 2.4 m): no change. Around 2.7 m: go up about 10%. 3 m or higher: go up about 20%, which usually means the next size.
  3. Is the room upstairs, or is the ceiling poorly insulated? Neither: no change. One of them: go up one size. Both: go up one size and talk to us about insulation.
  4. Does the room have big west or north-facing windows, or a lot of glass? No: no change. Yes: go up one size.

If you plan to use the unit as your main winter heater and you’re between two sizes, take the larger one.

Common sizes run roughly 2.5, 3.5, 5.0, 6.0, 7.1, 8.0 and 9.0 kW. If you land above about 9 kW for one space, two units, a multi-head system or ducted will do a better job than one big split.

Why book your install now?

The first hot spell in December sends half of Melbourne looking for an air conditioner at once. Booking in November leaves time for a site visit, any switchboard work and the install before summer, on a date you choose.

Newly installed split system indoor unit on a living room wall

Book a site visit or free quote

A sizing chart gets you close. A site visit gets it right. We’ll look at the room, the windows and where the outdoor unit will sit, recommend a unit, then check your switchboard so there are no surprises on install day. From there we supply the system and do the whole install, pipework, gas and power included.

To speed up your quote, have these ready:

  • The rooms you want to heat and cool, with rough measurements
  • A photo of your switchboard with the cover open
  • A photo of where you’d like the outdoor unit

Electrical Powerhaus is rated 4.9 stars from 188 Google reviews, and all our workmanship comes with our Lifetime Guarantee. If this is your first job with us, you’ll get 15% off, and pensioners and seniors always get 10% off.

Call 03 6358 2028 or request a free quote to book your site visit before summer.

[IMAGE 5: electrical-powerhaus-all-smiles-after-a-finished-job-p106.jpg]

Frequently asked questions

What size air conditioner do I need for a bedroom?

Most bedrooms need 2.0 to 3.5 kW. A small bedroom or study under 15 m² is usually fine with 2.0 to 2.5 kW. A main bedroom usually needs 2.5 to 3.5 kW, and an upstairs bedroom often needs the top of that range.

What size air conditioner do I need for an open-plan living area?

Open-plan areas of 50 to 70 m² usually need 6 to 9 kW. Measure the whole connected space. Above about 70 m², two units, a multi-head system or ducted usually works better.

Is it better to get a bigger air conditioner than I need?

No. An oversized unit switches on and off too often, which gives uneven temperatures, poor moisture removal, higher running costs and more wear. Pick the size that matches the room, or one just slightly above it.

Should I size my split system for heating or cooling in Melbourne?

Size for heating in most Melbourne homes. Reverse cycle units lose heating output on cold mornings, and most households here use them more in winter than summer. Check the cold zone rating on the energy label.

Do I need a new circuit for a split system air conditioner?

Yes. Each split system should have its own dedicated circuit with the right circuit breaker and safety switch protection, plus an isolator next to the outdoor unit. Running a new unit off an existing power circuit is a common cause of tripping.

Will I need a switchboard upgrade to install air conditioning?

Sometimes. Old ceramic fuse boards, boards with no safety switches and full boards may need an upgrade before a new air conditioning circuit goes in. We check this at quote time.

Can one company supply and install the whole split system?

Yes. Electrical Powerhaus supplies the unit and handles the full install: mounting, refrigerant pipework, gas charge, commissioning, the dedicated circuit and any switchboard upgrade. You don’t need to book a separate refrigerant technician.