Tracking down a pool circuit fault in Doncaster

Pool gear lives a hard life. Pumps, chlorinators and heaters sit outside in sun and rain, often a long cable run from the switchboard, and when something goes wrong it tends to show up as power that cuts in and out or a pump that will not run.

That was the starting point for this Doncaster job. The owner got in touch at the end of October about problems with the pool circuit, and we booked them in for Monday 2 November.

Step one: test the board

Our electrician started at the switchboard with insulation resistance and voltage tests. These tell you whether the cabling on a circuit is leaking current somewhere it should not, and they narrow down which circuit to chase.

Two things stood out at the board. The main switch was an isolator rather than a circuit breaker, which does not meet current requirements. And nine circuits were running on plain circuit breakers rather than individual safety switches. On a property with a pool and outdoor equipment, that is not where you want the protection to be.

Doncaster switchboard before the upgrade, with older circuit breakers and an isolator main switch
The switchboard before the upgrade.

Step two: find the fault

Testing pointed to one faulty power circuit, so we did a major fault find on it. That means disconnecting and removing the power points on the circuit, up to ten of them, and testing the cable between each point until the bad section shows itself. It is slow, careful work, but it is the only honest way to find a fault buried in a run of cable rather than guessing and swapping parts.

Electrician fitting individual safety switches to a Doncaster switchboard
Individual safety switches going in, one per circuit.

Step three: protect every circuit

With the fault find done, we went back to the board and:

  • Replaced the non-compliant isolator with a circuit breaker as the main switch
  • Replaced the existing circuit breakers on nine circuits with individual safety switches

Individual safety switches mean each circuit has its own earth leakage protection. If any one circuit develops a fault, only that circuit drops out, and it drops out fast enough to protect anyone touching the equipment. The rest of the house stays on.

We finished up on Friday 6 November, tested everything and handed over a certificate of compliance for the work.

Why this matters in Doncaster

A lot of Doncaster homes on the slopes below the hill went up in the 1960s and 70s, and many added a pool later. The pool circuit was often tacked onto a board that was already full, and the board itself was never brought up to date. We see the same pattern across Manningham.

Safety tip for pool owners

Press the test button on your safety switches every three months. Each one should trip straight away. If a safety switch will not trip, or if you have no safety switches at all, do not use the pool equipment until an electrician has checked it. Water and faulty wiring is the worst combination you can have at home.

Doncaster electricians, close by

Our Box Hill base is less than four kilometres from Doncaster. See more about our Doncaster electrical work, or read about safety switch installation and repair.

Pool pump tripping or a circuit that keeps dropping out? Call 03 6358 2028 or book online. New customers save 15% on their first service, and seniors and pensioners save 10% on every job. Rated 4.9 stars from 188 reviews, with a lifetime warranty on our workmanship.

Share the Post:

Request Free Quote*

Enter your details and we'll give you a call right away!

More Articles From The Blog